Background
Type: Conference Paper

Mid-infrared sensing of carbon monoxide in industrial glass furnaces

Journal: Optics InfoBase Conference Papers (21622701)Year: 2004Volume: Issue:
Willer, UlrikeKhorsandi A.a Schade W.Wondraczek, Lothar
Language: English

Abstract

The P(28) line is used to detect carbon monoxide directly in the atmosphere of a glass furnace. A concentration of 300 ppm is found, in good agreement with conventional measurements in the exhaust gas stream. © 2003 Optical Society of America.


Author Keywords

Other Keywords

Carbon monoxideOptical fibersConventional measurementsExhaust gas streamsIndustrial glassInfrared sensingMidinfraredGlass