Background
Type: Article

Analytical Technique for Analysis and Detection of Eccentricity Fault in Surface-Mounted Permanent Magnet Generators Using No-Load Voltage Signature

Journal: Electric Power Components and Systems (15325016)Year: 9 May 2018Volume: 46Issue: Pages: 957 - 973
Hassanzadeh M.-R. Faiz J.Kiyoumarsi A.a
DOI:10.1080/15325008.2018.1511008Language: English

Abstract

This paper presents a method for modeling the effects of static eccentricity, dynamic eccentricity, and mixed eccentricity faults on the electromotive force (emf) of the surface-mounted permanent magnet generators (SMPMGs). The model is based on the combination of conformal mapping method (complex relative permeance) and eccentricity relative air gap permeance and it presents explicit formulas for no-load magnetic field distribution, magnetic flux, and emf in SMPMGs under different eccentricity fault types, some have not been so far considered elsewhere. The analytical and also numerical results show that there are some side-band components in the emf signature which can be used as eccentricity fault index. Analytical results validate by time-stepping finite element method (TSFEM) results. © 2018, © 2018 Taylor & Francis Group, LLC.